Thermal Material Testing
Testing Systems
Test system | System data | Application |
---|---|---|
Fogging-Tester HAAKE and THERMO FISHER SCIENTIFIC | Temperature range: up to 100°C | Quantification of vaporized non-permanent parts -IR analysis of fogging condensation |
Warming and drying cabinets MEMERT BINDER HERAEUS | Circulating / fresh air Temperature range: RT – 250°C | Determination of aging performance of elastomer and plastics as function of temperature and oxygen rate |
Freezer and cold cabinets NATIONAL LAB KRYOTEC HERAEUS | Temperature range: (-70 – +10) °C Additional equipment: drop-ball, folding and buckling devices |
Determination of aging performance of elastomer and plastics as function of temperature |
Suspendet thermostats HAAKE | Temperature range: (30 – 150) °C | Determination of elastomer's resistance to inflation |
Pressure pieces OSWALD-STEIN and KLIEWE | Pressure range: max 10 bar Temperature range: RT – 160 °C |
Determination of elastomer's resistance to inflation under pressure in various media |
Thermal-dimensional stability testbed KARG | Temperature range: (25 – 230) °C, Load as bending stress / force -HDT procedure A / B: (1.80 / 0.45) MPa -VICAT procedure A / B: (10 / 50) N | Determination of heat distortion temperature (HDT) and VICAT temperature of plastics under load |
Hot air contraction devices TESTRITE | Temperature range: RT – 250 °C Force range: 0 – 20 N Travel: 0 – 35 % |
Determination of linear length and forces changes of tissue as a function of temperature |
Ignitability tester EIGENBAU | Temperature range: (300 – 400) °C Flow rate: (0 – 5) l/min Medium: Oxygen |
Determination of resistance to self ignition of hoses |