Resistance to Radiation and Ozone Testing

Testing Systems

Test system System data Application
Electromechanical xenon radiation testers 150S Synchronism and alternating wavelength interval: (280 – 800) nm
Exposure rate: (835 – 1570) Wm²
Cycle type spray irrigation/dry: e.g.1/29; 3/17; 5/25; 10/20; 18/102
Filter: UV, window glass, IR
Sample size: e.g. (190*64) mm
Determination of color, surface and mechanical changes after artificial weathering or irradiation, among other things light fastness, light crack formation, light induced contact discoloration
UVA irradtiation system SOL 2/F400 Wavelength: (315 – 800) nm
Exposure rate: (300 – 1000) Wm²
Sample size: max DIN A4
Determination of color, surface and mechanical changes after artificial irradiation
Ozone test consoles ARGENTOX Concentration O3: (25 – 500) pphm
Temperature range: (-10 – +50)°C
Relative humidity: (0 – 100)%
Determination of resistance to cracking under static stress with strip samples and hoses
Electromechanical ozone test console ARGENTOX Concentration O3: (25 – 500) pphm
Temperature range: (-10 – +50)°C
Relative humidity (0 – 100)%
Strain: (0 – 30)%
Frequency: (0 – 0.5) Hz
Determination of resistance to cracking under static and dynamic stress with strip samples
Analysis equipment method B, in accordance with DIN 53509-2 EIGENBAU Reference method for the determination of ozone concentration in test chambers